Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Braz. j. otorhinolaryngol. (Impr.) ; 88(supl.1): 63-69, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1420810

ABSTRACT

Abstract Introduction Obstructive sleep apnea is a frequent entity in childhood that can lead to important consequences for the health and children's quality of live. Polysomnography is the gold-standard exam to diagnose obstructive sleep apnea, but it is expensive, complex, and poorly affordable in Brazil. The pediatric sleep questionnaire has shown to be a valuable screening test for obstructive sleep apnea. It is a simple questionnaire with good sensitivity and specificity compared to polysomnography in the countries where it has been validated. Objective Translation and cross-cultural adaptation of the pediatric sleep questionnaire (PSQ), into Brazilian Portuguese. Methods The translation of the PSQ into Brazilian Portuguese was carried out in accordance with good practices. The validated and adapted questionnaire was applied to parents/caregivers of 60 children (40 of them with obstructive sleep apnea and 20 controls) aged 2-18 years. Retest was applied to 30 children with obstructive sleep apnea. The following tests were performed: internal consistency, test-retest, validation of questionnaire (the latter by ROC curve). Results Brazilian PSQ has shown high internal consistency by Cronbach's alpha (0.86 for the total test, 0.83 for subscale "snoring", 0.64 for "sleepiness" and 0.65 for "behavior"). Test-retest presented a correlation of 0.89 for subscale "snoring", 0.93 for "sleepiness" and 0.86 for "behavior". Accuracy by ROC curve was 0.99. Nine was considered the optimal value to discriminate patients with obstructive sleep apnea from controls, with a sensitivity of 0.92 and specificity of 1.0. Conclusion The translation and cross-cultural adaptation of the PSQ into Brazilian Portuguese proved to be successful. In places with difficult access to polysomnography, PSQ can be a useful tool in screening and follow-up of children with obstructive sleep apnea.


Resumo Introdução A apneia obstrutiva do sono é uma doença comum na infância que pode trazer consequências importantes para a saúde e qualidade de vida das crianças. O exame padrão‐ouro para o diagnóstico (polissonografia) é um exame caro, complexo e disponível em poucos centros. O pediatric sleep questionnaire, PSQ, tem demonstrado ser um bom teste de triagem para apneia obstrutiva do sono, por ser um questionário simples e com boa sensibilidade e especificidade quando comparado à polissonografia nos países em que foi validado. Objetivo Tradução e adaptação transcultural do PSQ para o português do Brasil. Método Foi feita a tradução do PSQ para o português do Brasil, de acordo com as boas práticas. O questionário validado e adaptado foi aplicado aos pais/responsáveis de 60 crianças com 2-18 anos, 40 com apneia obstrutiva do sono e 20 controles. O reteste foi feito em 30 crianças com apneia obstrutiva do sono. Foram avaliados: consistência interna, teste‐reteste, validação do conteúdo e acurácia do questionário, pela curva ROC (do inglês receiver operating characteristic curve). Resultados O PSQ‐Brasil apresentou alta consistência interna, pelo coeficiente Alfa de Cronbach (0,86 para o teste total; 0,83 para o subdomínio "ronco"; 0,64 para "sonolência" e 0,65 para "comportamento". O teste‐reteste teve concordância de 0,89 para o subdomínio "ronco"; 0,93 para sonolência" e 0,86 para "comportamento". A acurácia medida pela curva ROC foi de 0,99. O valor de 9,0 foi considerado ideal para diferenciar os pacientes com apneia obstrutiva do sono e controles, com sensibilidade de 0,92 e especificidade de 1,0. Conclusão A tradução e adaptação transcultural do PSQ para o português do Brasil mostrou‐se bem‐sucedida. Em locais com dificuldade de acesso à polissonografia, o PSQ pode ser uma ferramenta útil na suspeição diagnóstica e seguimento das crianças com apneia obstrutiva do sono.

2.
Arq. bras. oftalmol ; 84(3): 203-208, May-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1248956

ABSTRACT

ABSTRACT Purpose: To comparatively assess the macular sensitivity threshold of microperimetry and the fixation stability between the first (right) and second (left) tested eye of normal participants. Methods: Thirty healthy patients were randomly assigned to two groups. The participants underwent microperimetry in the fast mode and expert mode in groups I and II, respectively. Each participant underwent a single test and the right eye was tested first. Results: The mean macular sensitivity threshold (± standard deviation [SD]) was 24.5 ± 2.3 dB and 25.7 ± 1.1 dB in the first (right) and second (left) eyes of group I, respectively (p=0.0415) and 26.7 ± 4.5 dB and 27.3 ± 4.0 dB in the first (right) and second (left) eyes of group II, respectively (p=0.58). There was no statistically significant difference between eyes in either group (p=0.1512). Regarding fixation stability (evaluated in the microperimetry expert mode group), the mean ± SD percentage of fixation points within the 1-degree central macula (P1) was 87.9 ± 11.5% in the right eye and 93.8 ± 6.6% in the left eye. The paired t-test did not show a statistically significant difference between eyes (p=0.140). Mean ± SD P2 value was 95.5 ± 4.9% in the right eye and 98.5 ± 2.1% in the left eye. The analysis demonstrated an increase in the percentage of fixation points in the second tested eye compared with the first one (paired t-test= 2.364; p=0.034). There was a negative correlation between the macular sensitivity threshold of the right eye and the duration of the examination for both groups (microperimetry expert mode: r=-0.717; p=0.0026; microperimetry in the fast mode: r=-0.843; p<0.0001). Conclusion: Mean macular sensitivity threshold was higher in the second tested eye in the microperimetry in the fast mode group and was similar in both eyes in the expert mode. Our data suggest that comprehension of the examination by the individual may impact the results of the microperimetry test.(AU)


RESUMO Objetivo: Avaliar comparativamente o limiar de sensibilidade macular da microperimetria e a estabilidade de fixação entre o primeiro (direito) e o segundo (esquerdo) olhos testados de indivíduos normais. Métodos: Trinta pacientes saudáveis foram divididos aleatoriamente em 2 grupos. Os participantes foram submetidos à microperimetria no "fast mode" e no "expert mode" no grupo I e II, respectivamente. Cada participante foi submetido a um único teste e o olho direito foi testado primeiro. Resultados: No grupo I, o limiar médio de sensibilidade macular (± DP) foi de 24,5 ± 2,3 dB e 25,7 ± 1,1 dB nos olhos direito e esquerdo, respectivamente (p=0,0415). No grupo II foi de 26,7 ± 4,5 dB e 27,3 ± 4,0 dB nos olhos direito e esquerdo, respectivamente (p=0,58). Não houve diferença estatisticamente significativa entre os olhos dos dois grupos (p=0,1512). Em relação à estabilidade de fixação (avaliada no grupo microperimetria no "expert mode"), a média das porcentagens dos pontos de fixação dentro do 1 grau central da mácula (P1) ± DP foi de 87,9 ± 11,5% no olho direito e de 93,8 ± 6,6% no olho esquerdo. O teste t pareado não mostrou diferença estatística entre os olhos (p=0,140). O valor médio de P2 ± DP foi de 95,5 ± 4,9% no olho direito e 98,5 ± 2,1% no olho esquerdo. Foi demonstrado um aumento na porcentagem de pontos de fixação no segundo olho testado quando comparado ao primeiro (teste t pareado= 2,364; p=0,034). Houve correlação negativa entre o limiar de sensibilidade macular do olho direito e a duração do exame nos dois grupos (microperimetria no "expert mode": r=-0,717; p=0,0026; microperimetria no "fast mode": r=-0,843; p <0,0001). Conclusão: O limiar médio de sensibilidade macular foi maior no segundo olho testado no grupo microperimetria no "fast mode" e foi semelhante nos dois olhos no "expert mode". Nossos dados sugerem que a compreensão do exame pelo indivíduo pode impactar nos resultados da microperimetria.(AU)


Subject(s)
Humans , Visual Acuity , Fixation, Ocular , Macula Lutea/diagnostic imaging , Visual Fields , Bias
3.
Arq. bras. oftalmol ; 84(3): 282-296, May-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1248965

ABSTRACT

ABSTRACT This review is intended to describe the therapeutic approaches for corneal blindness, detailing the steps and elements involved in corneal wound healing. It also presents the limitations of the actual surgical and pharmacological strategies used to restore and maintain corneal transparency in terms of long-term survival and geographic coverage. In addition, we critically review the perspectives of anabolic agents, including vitamin A, hormones, growth factors, and novel promitotic and anti-inflammatory modulators, to assist corneal wound healing. We discuss the studies involving nanotechnology, gene therapy, and tissue reengineering as potential future strategies to work solely or in combination with corneal surgery to prevent or revert corneal blindness.(AU)


RESUMO O presente trabalho traz uma revisão das abordagens terapêuticas para a cegueira da córnea. O estudo detalha as etapas e os elementos envolvidos na cicatrização da córnea. Ele mostra as limitações das estratégias cirúrgicas e farmacológicas usadas para restaurar e manter a transparência da córnea em termos de sobrevida a longo prazo e alcance geográfico. As perspectivas dos agentes anabólicos, incluindo vitamina A, hormônios, fatores de crescimento e novos moduladores pró-mitóticos e anti-inflamatórios para auxiliar a cicatrização da ferida na córnea, são revisadas criticamente. Aqui, apresentamos estudos envolvendo nanotecnologia, terapia gênica e reengenharia de tecidos como possíveis estratégias futuras para atuar de maneira isolada ou combinada com a cirurgia da córnea para prevenir ou reverter a cegueira corneana.(AU)


Subject(s)
Humans , Blindness/prevention & control , Blindness/therapy , Corneal Injuries/prevention & control , Corneal Injuries/therapy , Stem Cells , Vitamin A/therapeutic use , Genetic Therapy/instrumentation , Nanotechnology/instrumentation , Intercellular Signaling Peptides and Proteins/therapeutic use , Hormones/therapeutic use , Anti-Inflammatory Agents/therapeutic use
4.
Arq. bras. oftalmol ; 83(6): 526-534, Nov.-Dec. 2020. tab, graf
Article in English | LILACS | ID: biblio-1153085

ABSTRACT

ABSTRACT Purpose: To compare visual acuity, macular thickness, and the area of active neovascularization based on fluorescein angiography outcomes associated with standard single-spot panretinal photocoagulation in the Early Treatment Diabetic Retinopathy Study (ETDRS) pattern combined with intravitreal ranibizumab injection versus multiple-spot full scatter (PASCAL) panretinal photocoagulation combined with intravitreal ranibizumab injection versus intravitreal injection alone in patients with proliferative diabetic retinopathy. Methods: Patients with proliferative diabetic retinopathy and no prior laser treatment were randomly assigned to receive three different types of treatment. Panretinal photocoagulation in the ETDRS group was administered in two sessions (weeks 0 and 2), and panretinal photocoagulation in the PASCAL group was administered in one session (week 0). Intravitreal injection of ranibizumab was administered at the end of the first laser session in both the ETDRS and PASCAL groups and at week 0 in the intravitreal injection group. Comprehensive ophthalmic evaluations were performed at baseline and every 4 weeks through week 48. Results: Thirty patients (n=40 eyes) completed the 48-week study period. After treatment, best-corrected visual acuity was significantly (p<0.05) improved at all follow-up visits in the group receiving intravitreal injection alone, at all but week 4 in the ETDRS group, and at all but weeks 4 and 8 for the PASCAL group. A significant decrease in central subfield macular thickness was observed in the PASCAL group at weeks 4, 8, and 48; only at week 48 in the intravitreal injection group; and never in the ETDRS group. There was no significant difference among the three treatment groups with respect to change from baseline to week 48 in best-corrected visual acuity, central subfield macular thickness, or fluorescein leakage from active neovascularization in best-corrected visual acuity, central subfield macular thickness, or fluorescein leakage from active neovascularization. Conclusions: Intravitreal injection alone or combined with single- or multiple-spot panretinal photocoagulation yielded similar outcomes with respect to mean change in best-corrected visual acuity, central subfield macular thickness, and fluorescein leakage from active neovascularization at up to one-year of follow-up. All subjects provided written informed consent to participate (NCT02005432 in clinicaltrials.gov).


RESUMO Objetivo: Comparar as medidas de acuidade visual, espessura macular central e área de neovasos ativos na an­giofluoresceinografia submetidos a panfotocoagulação retiniana padrão ETDRS associado a injeção intravítrea de ranibizumabe versus panfotocoagulação padrão PASCAL associado a injeção intravítrea de ranibizumabe versus somente injeção intravítrea de ranibizumabe em pacientes com retinopatia diabética pro­liferativa. Métodos: Pacientes com retinopatia diabética proliferativa e virgens de tratamento, randomicamente divididos nas três diferentes terapias retinianas. Panfotocoagulação no grupo ETDRS em 2 sessões (semanas 0 e 2) e no grupo PASCAL, na semana 0. Injeção intravítrea de ranibizumabe realizado ao fim da primeira sessão de laser em ambos os grupos: ETDRS e PASCAL, e na semana 0 no grupo injeção intravítrea de ranibizumabe. Avaliações oftalmológicas, tomografia de coerência óptica e angiofluoesceinografia realizados na visita basal e a cada 4 semanas por 48 semanas. Resultados: Trinta pacientes (n=40 olhos) completaram as 48 semanas de seguimento. Após o tratamento, a acuidade visual melhorou significantemente em todas a visitas no grupo injeção intravítrea de ranibizumabe (p<0,05); em todas exceto na semana 4 no grupo ETDRS, em todas exceto nas semanas 4 e 8 no grupo PASCAL. Redução significativa na espessura do subcampo central foi evidenciada no grupo PASCAL nas semanas 4, 8 e 48; somente na semana 48 no grupo injeção intravítrea de ranibizumabe, e em nenhuma visita no grupo ETDRS. Redução também na área de neovasos ativos em todas as visitas em todos os grupos. Não houve diferença significante entre os três grupos com relação a mudança media na medidas de acuidade visual, espessura macular central ou área de neovasos ativos da visita inicial para a semana 48. Conclusões: Somente IVB ou este associado a panfotocoagulação ETDRS ou PASCAL, apresentaram efeitos semelhantes em relação a medidas de acuidade visual, espessura do subcampo central e área de neovasos ativos no decorrer de 48 semanas de seguimento.


Subject(s)
Humans , Angiogenesis Inhibitors/therapeutic use , Diabetes Mellitus , Diabetes Mellitus/drug therapy , Diabetic Retinopathy , Diabetic Retinopathy/surgery , Diabetic Retinopathy/drug therapy , Treatment Outcome , Laser Coagulation , Intravitreal Injections , Ranibizumab/therapeutic use
5.
Arq. bras. oftalmol ; 83(1): 28-32, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088952

ABSTRACT

ABSTRACT Purpose: The purpose of the present work is to measure the interocular upper lid contour symmetry using a new method of lid contour quantification. Methods: The Bézier curve tool of the Image J software was used to extract the right and left upper eyelid contours of 75 normal subjects. Inter-observer variability of 29 right lid contours obtained by two independent observers was estimated using the coefficient of overlap of two curves and an analysis of the differences of the contour peak location. A two-way analysis of variance was used to test the mean value of the coefficient of overlap of the right and left contours in males and females and lid segments. The same analysis was performed to compare the location of the contour peak of the right and left contours. Results: The coefficient of contour overlap obtained by independent observers ranged from 93.5% to 98.8%, with a mean of 96.1% ± 1.6 SD. There was a mean difference of 0.02 mm in the location of the contour peak. Right and left contour symmetry did not differ between females and males and was within the range of the method variability for contour overlap and location of the contour peak. Conclusions: The upper eyelid contour is highly symmetrical. Bézier lines allow a quick and fast quantification of the lid contour, with a mean inter-observer variability of 3.9%.


RESUMO Objetivo: O objetivo do presente estudo é mensurar a simetria interocular do contorno da pálpebra superior por meio de um novo método de quantificação de contorno palpebral com curvas de Bézier. Métodos: A ferramenta de curva de Bézier do software ImageJ foi utilizada para extrair os contornos palpebrais direito e esquerdo de 75 sujeitos normais. A variabilidade interobservador de 29 contornos palpebrais do olho direito obtidos por dois observadores diferentes foi estimada pelo coeficiente de superposição de duas curvas e pela análise das diferenças das posições do pico do contorno. Análise de variância de dois fatores foi empregada para testar a média do coeficiente de superposição entre os contornos direito e esquerdo quanto ao sexo e segmento palpebral. A mesma análise foi utilizada para comparar a localização do pico do contorno dos olhos direito e esquerdo. Resultados: O coeficiente de superposição obtidos por observadores independentes variou ente 93,5% e 98,8% com média de 96,1% ± 1,6 DP. A diferença das médias da localização do pico do contorno palpebral foi de 0,02 mm. A simetria entre os contornos dos olhos direito e esquerdo não diferiu entre o sexo feminino e masculino e esteve na faixa de variabilidade do método para o coeficiente de superposição e localização do pico do contorno. Conclusões: O contorno da pálpebra superior é altamente simétrico. As linhas Bézier permitem uma rápida e prática quantificação do contorno palpebral com uma média de variabilidade interobservador de 3,9%.


Subject(s)
Humans , Male , Female , Adult , Eyelids/anatomy & histology , Facial Asymmetry/diagnosis , Reference Values , Computer Simulation , Signal Processing, Computer-Assisted , Software
7.
Arq. bras. oftalmol ; 73(4): 329-332, July-Aug. 2010. ilus, tab
Article in English | LILACS | ID: lil-560604

ABSTRACT

PURPOSE: To determine if the distribution of inter-blink time intervals is constant with repeated measurements with and without topical ocular anesthesia. METHODS: Inter-blink time was measured in 15 normal subjects ranging from 19 to 32 years (mean ± SD= 23.9 ± 3.20) with the magnetic search coil technique on 3 different occasions, the last one with topical ocular anesthesia. RESULTS: One-way analysis of variance for repeated measurements showed that topical anesthesia significantly reduced the blink rate (blinks per minute), which was constant in the first two measurements (F=8.27, p=0.0015. First measurement: mean ± SD= 13.7 ± 7.8; second measurement: 13.1 ± 8.5 SD; with topical anesthesia: = 7.2 ± 4.6). However, distributions shape was not affected when the blink rate was reduced. The three distributions followed a Log Normal pattern, which means that the time interval between blinks was symmetrical when the time logarithm was considered. CONCLUSIONS: Topical ocular anesthesia reduces the rate of spontaneous blinking, but does not change the distribution of inter-blink time interval.


OBJETIVOS: Determinar se a distribuição dos intervalos do piscar espontâneo se mantém em medidas repetidas com e sem anesthesia tópica ocular. MÉTODOS: Os intervalos entre movimentos de piscar da pálpebra superior foram medidos com rastreamento magnético (Magnetic Search Coil) em 15 sujeitos (11 do sexo masculino) normais com idades entre 19 a 32 anos (média 23,86 ± 3,20 dp anos). RESULTADOS: Análise de variância unifatorial para medidas repetidas mostrou que a anesthesia tópica ocular diminuiu significativamente a frequência média (número de blinks/minuto) do piscar espontâneo, a qual se manteve constante nas duas primeiras medidas (F=8,27, p=0,0015. Primeira medida 13,7 ± 7,8 DP; segunda medida 13,1 ± 8,5; com anestesia tópica 7,2 ± 4,6). No entanto, a forma da distribuição nas 3 medidas obedeceu uma distribuição do tipo Log Normal, de modo que os intervalos de piscar foram normalmente distribuídos quando o logaritmo do intervalo foi considerado. CONCLUSÕES: A anesthesia tópica ocular diminui significativamente a frequência de piscar, mas não altera a distribuição dos intervalos do piscar espontâneo.


Subject(s)
Adult , Female , Humans , Male , Young Adult , Anesthesia , Anesthetics, Local/pharmacology , Blinking/drug effects , Ophthalmic Solutions/pharmacology , Administration, Topical , Analysis of Variance , Blinking/physiology , Statistics, Nonparametric , Time Factors
8.
Arq. bras. oftalmol ; 73(3): 231-234, jun. 2010. ilus, graf
Article in Portuguese | LILACS | ID: lil-555062

ABSTRACT

Objetivo: Verificar a frequência de assimetrias superiores a 0,2 na razão escavação/disco em uma população de adolescentes. Métodos: Retinografias de ambos os olhos de 123 jovens foram digitalizadas na resolução de 300 pixels por polegada (300 dpi), 8 bits, padrão de cor RGB. Para a realização das medidas foi utilizado o software Image J, versão 1.42, desenvolvido pelo National Institute of Health (NIH), plataforma Java versão 1.6. Resultados: Os valores das diferenças, entre os dois olhos do mesmo indivíduo, na razão das medidas do diâmetro vertical da escavação/diâmetro vertical do disco óptico variaram de 0 a 0,30. A média das diferenças foi 0,07, a mediana 0,06 e o desvio padrão 0,05. Assimetrias de até 0,06 apresentaram frequência de 54,4 por cento e assimetrias de até 0,1 estiveram presentes em 79,7 por cento da amostra. Dois indivíduos (1,63 por cento) apresentaram assimetrias superiores a 0,2. Conclusão: A frequência de assimetrias no grupo de adolescentes estudado é similar à encontrada em estudos realizados com população adulta normal.


Purpose: To determine the frequency of asymmetries greater than 0.2 in the cup-to-disc ratio of a population of adolescents. Methods: Fundus photographs of both eyes of 123 adolescents were digitized at the resolution of 300 pixels per inch (300 dpi), 8 bits, with a RBG color pattern. The measurements were performed using the Image J software, version 1.42, developed by the National Institutes of Health (NIH), Java platform version 1.6. Results: The values of the differences in the cup-to-disc ratio between the two eyes of the same individual ranged from 0 to 0.30. The mean difference was 0.07, the median 0.06 and the standard deviation 0.05. About 54.4 percent of the studied population had asymmetries up to 0.06 and 79.7 percent had asymmetries up to 0.1. Two individuals presented asymmetries of more than 0.2, corresponding to 1.63 percent of the evaluated subjects. Conclusion: The frequency of asymmetries in the group of adolescents studied was similar to that detected in studies of the normal adult population.


Subject(s)
Adolescent , Female , Humans , Male , Fundus Oculi , Optic Disk/anatomy & histology , Cross-Sectional Studies , Image Interpretation, Computer-Assisted , Reference Values
SELECTION OF CITATIONS
SEARCH DETAIL